Best in Class – Waste Oil Boiler Technology. Deliver the Hottest heat for radiant flooring and potable water.
Capacity | Heats up to 3,500 square feet (approximately one to four service bays) |
BTU Input | 140,000 BTU (41.6 kW) per hour |
Fuel Flow Rate | 1.0 gallons/hour (3.78 liters/hour) |
Heat Rise Over Input Air | 100-120º F (37.8-48.9º C) |
Airflow | 1000 cfm (28cu. m/min) |
Exhaust Flue Diameter | 6” or 8” |
Dimensions | 18”H x 18”W x 92”L (46cm H x 46cm W x 234cm L) |
Weight | 295 lbs (132 kg) |
Exclusive - Designed to prevent corrosion, warping, and weld breakage.
Built to last decades, not years. Open design for easy cleaning.
Tracks runtime
Patented - Rapidly heats the widest range of viscosities of used oil,
synthetic oils, and other acceptable fuels.
Built-in so you don’t have to connect to and rely on shop air.
Providing 24/7 heating availability.
Patented - Reliable, consistent fuel delivery regardless of fuel type
(up to 90W) with no manual adjustments.
Exclusive -
*Included with fuel delivery kits, complete systems, and with heater only.
Exclusive
1. Pump can be mounted at the fuel source—instead of on top of the tank
—so the pump is flooded with used oil, not air!
2. Fuel pick-up is six inches above the bottom of the tank,
above water and sludge, ensuring only used oil is sent to the furnace.
3. Easy spin-on stainless mesh filter.
Patented - This patented design creates a hotter flame than competitor brands for complete
fuel combustion and the highest heat output. Less ash is produced resulting in longer
maintenance intervals than competitor brands.
This convenient combination makes cleaning the chamber faster
and easier than any other brand. One tool, 30 minutes or less.
Visual indicator of how much used oil is in your tank.
Makes it simple to purge water or other contaminants
that naturally settle in the bottom of the tank.
Stainless steel interior, double-wall fl ue kits are UL-listed and meet local codes.
*Standard for a complete system or sold separately.
*Minimum 12ft ceiling height for a tank-mounted heater.
*Wall mount brackets available.